Item | Specification and Technical Data |
Input voltage U1 | 220V/380V/500/690V+15%;signal/three-phase power |
Input frequency f1 | 50...60Hz+5Hz |
Output voltage U2 | 0..U1 (V)(The maximum output voltage equals the input power voltage.) |
Output frequency f2 | 0-599Hz |
Carier frequency | 2-8 KHz (The device can intelligently and automatically make optimal adjustmentaccording to load characteristics and drive temperature.) |
Input voltageunbalance degree | Maximum: +3% of rated inter-phase input voltage |
Efficiency | ≈98% (when operating at rated power) |
Speed range | 0-599Hz(0~30000 rpm,60000rpm is optional ) |
Resolution of given speed | Digital setting:1RPM Analog setting: 0.025% of maximum RPM |
Control mode | Open-loop vector control/close-loop vector control |
Starting speed | 200%@ 0.25Hz@ SVC control 200% @0Hz@ FVC control |
Speed ratio | 1:200@ SVC control 1:3000@ FVC control |
Overload capacity | Heay load application: 60s at 150% rated current @40°C. The time depends on the drive temperature under other conditions. General application: 60s at 120% rated curent @40°C. The time depends on the drive temperature under other conditions. |
Torque boost | Automatic torque boost. Manual torque boost 0.1%-30% |
Built-in PID | Conveniently achieve the process control close-loop control system |
Torque limiting and control | The torque is automatically limited operating (to avoid frequent overcurrent jumping fault due totoo large torque). |
Protection function | Output shortcircuit protection, input & output phase loss protection, overcurrent protection, overvoltage protection,undervoltage protection, overheat protection, overload protection, brake chopper overload protection, brake chopper shortcircuit protection, brake resistor overload protection |
Bus communication | The standard configuration uses the built-in Modbus/communication, which can beextended to Profibus-DP, CANopen bus communication. Etc. |
Command input mode | Control keyboard input, control terminal input bus communication input which can beswitched mutually. |
Speed reference mode | Digital giving, analog voltage (current) giving, pulse giving, bus communication giving and PID giving, which are mutually switched. |
Input terminal (input) | The followings are included in standard configuration :6 (FO) /7 (F1 and above) digital input terminals, where,DI6 (FO) DI7 (F1 and above)supports the maximum of 50 kHz high-speed pulse input.2 (F0) /3 (F1 and above) analog input terminals (where, at least 2 supports 0-10V voltageinput or 0-20 mA or 4-20mA voltage input)The followings are extended as cards :5 digital input terminals2 analog input terminals, supporting input of -10V to+10V voltage (Optional) |
Output terminal (output) | The followings are included in standard configuration:1 high-speed pulse output terminal (supporting 0-50 kHZ square signal output )1 (FO) /2 (F1 and above) digital output terminals1 (F0) 12 (F1 and above) relay output terminals1 (F0) 12 (F1 and above) analog output terminals (supporting0-10V voltage outputor 0-20mA or 4-20 mA voltage output) |
Protection grade | IP20 (UL-open type), (the medium cavity with air vents on two sides for some F0** models)Electrical cavity full closed design for small- and medium-power models, Top/Left and rightsides can reach IP40 |